produced by Ansell Lighting Design Department Page 1/1129873 Moxy Stratford Plant Room Only Lighting Design 170802Moxy Stratford Plant Room Installati...
5 downloads
20 Views
363KB Size
Moxy Stratford Plant Room Installation : Proposed Lighting Layout Project number
: 99-29873-MG
Customer
: Cordant Technical
Processed by
: Tom Reid
Date
: 02.08.2017
Project description: Calculation based on standard reflectances. Room/exterior area dimensions and floor to ceiling/mounting heights issued from wholesaler. PLEASE NOTE: All room/exterior area dimensions to be checked on-site prior to installation. Lighting designed to CIBSE guidelines where applicable and/or client requirements, all stated lux values are for overall averages across the room reference plane. If dimmable luminaires have been specified, then it is the responsibility of the contractor to establish which dimming ballasts/system is required by the lighting control ethos/specification. Emergency lighting design conforms to BS5266/EN1838 where applicable. Please note that ‘points of emphasis’ such as locations of fire fighting equipment also require emergency lighting, these locations are to be confirmed by contractor. Please note that the emergency lighting calculation MUST be produced using the emergency lighting calculation facility within this program, failure to use the correct method will show false results. Specified recessed modules are to be mounted in suspended tile ceiling only, exact locations of luminaires are subject to change as location of ceiling tiles not given.
The following values are based on exact calculations on calibrated lamps, luminaires and their arrangement. In practice, gradual divergences can occur. Guarantee claims for luminaire data are excluded. Relux and the luminaire manufacturers accept no liability for consequential damage and damage which is occasioned to the user or to third parties.
produced by Ansell Lighting Design Department 29873 Moxy Stratford Plant Room Only Lighting Design 170802
Page 1/11
Object Installation Project number Date
: : : :
Moxy Stratford Plant Room Proposed Lighting Layout 99-29873-MG 02.08.2017
1
Luminaire data
1.1
ANSELL, Emergency - IP65 Owl L... (ATSLED/3NM/IP65/ST)
1.1.1 Data sheet Manufacturer: ANSELL
ATSLED/3NM/IP65/ST Escape luminaires Emergency - IP65 Owl LED Twin Spot ATSLED/3NM/IP65/ST Emergency Twin Spots IP65 Owl LED Twin Spot Supplied c/w Integral Driver LED 10W Non-Maintained Self-Test Self-test Twin LED emergency floodlight for industrial applications Robust white moulded enclosure Exceeds performance of 2x20W halogen equivalent Moulded polycarbonate heads Luminaire arrangement for: ATSLED/3NM/IP65/ST x[m] 0.000 0.000
ATSLED/3NM/IP65/ST_H : ATSLED/3NM/IP65/ST_H :
Position y[m] -0.085 0.085
z[m] 0.125 0.125
Z[°] 45 315
Rotation C0[°] 0 0
C90[°] 45 45
ATSLED/3NM/IP65/ST_H
Luminaire data Luminaire efficiency Luminaire efficacy Classification CIE Flux Codes UGR 4H 8H Control gear Luminous flux
: : : : : : :
110.5%
Dimensions
:
130 mm x 100 mm x 70 mm
A60 99.0% 1.0% 74 93 98 99 110 16.1 / 15.0 Electronic ballast 488.4 lm
Equipped with Quantity Designation Colour Luminous flux
: : : :
1
442 lm
produced by Ansell Lighting Design Department 29873 Moxy Stratford Plant Room Only Lighting Design 170802
Page 2/11
Object Installation Project number Date
: : : :
Moxy Stratford Plant Room Proposed Lighting Layout 99-29873-MG 02.08.2017
1
Luminaire data
1.1
ANSELL, Emergency - IP65 Owl L... (ATSLED/3NM/IP65/ST)
1.1.1 Data sheet
ATSLED/3NM/IP65/ST_H
Luminaire data Luminaire efficiency Luminaire efficacy Classification CIE Flux Codes UGR 4H 8H Control gear Luminous flux
: : : : : : :
110.5%
Dimensions
:
130 mm x 100 mm x 70 mm
A60 99.0% 1.0% 74 93 98 99 110 16.1 / 15.0 Electronic ballast 488.4 lm
Equipped with Quantity Designation Colour Luminous flux
: : : :
1
442 lm
produced by Ansell Lighting Design Department 29873 Moxy Stratford Plant Room Only Lighting Design 170802
Page 3/11
Object Installation Project number Date
: : : :
Moxy Stratford Plant Room Proposed Lighting Layout 99-29873-MG 02.08.2017
2
Plant Room - Twin spot
2.1
Description, Plant Room - Twin spot
2.1.1 Floor plan [m] 22
N
20 18 16 14 12 10 8 6 4 2 0 -6
Wall x 1 63.29 m 2 62.07 m 3 44.60 m 4 51.83 m Floor Ceiling Room height Height of reference plane
-4
y 24.09 m 47.29 m 38.47 m 24.07 m
-2
0
2
Length 11.46 m 23.23 m 19.57 m 16.11 m
4
6
8
10
[m] 1 : 250
Reflectance 50.0 % 50.0 % 50.0 % 50.0 % 20.0 % 70.0 %
5.00 m ----
produced by Ansell Lighting Design Department 29873 Moxy Stratford Plant Room Only Lighting Design 170802
Page 4/11
Object Installation Project number Date
2.1
: : : :
Moxy Stratford Plant Room Proposed Lighting Layout 99-29873-MG 02.08.2017
Description, Plant Room - Twin spot
2.1.2 3D view, View 1
produced by Ansell Lighting Design Department 29873 Moxy Stratford Plant Room Only Lighting Design 170802
Page 5/11
Object Installation Project number Date
2.1
: : : :
Moxy Stratford Plant Room Proposed Lighting Layout 99-29873-MG 02.08.2017
Description, Plant Room - Twin spot
2.1.3 3D view, View 2
produced by Ansell Lighting Design Department 29873 Moxy Stratford Plant Room Only Lighting Design 170802
Page 6/11
Object Installation Project number Date
: : : :
Moxy Stratford Plant Room Proposed Lighting Layout 99-29873-MG 02.08.2017
2
Plant Room - Twin spot
2.2
Calculation results, Plant Room - Twin spot
2.2.1 3D luminance, View 1
Luminance in the scene Minimum: Maximum:
: 0 cd/m² : 19.2 cd/m²
produced by Ansell Lighting Design Department 29873 Moxy Stratford Plant Room Only Lighting Design 170802
Page 7/11
Object Installation Project number Date
2.2
: : : :
Moxy Stratford Plant Room Proposed Lighting Layout 99-29873-MG 02.08.2017
Calculation results, Plant Room - Twin spot
2.2.2 3D luminance, View 2
Luminance in the scene Minimum: Maximum:
: 0 cd/m² : 19.2 cd/m²
produced by Ansell Lighting Design Department 29873 Moxy Stratford Plant Room Only Lighting Design 170802
Page 8/11
Object Installation Project number Date
: : : :
Moxy Stratford Plant Room Proposed Lighting Layout 99-29873-MG 02.08.2017
2
Plant Room - Twin spot
2.3
Calculation results, Plant Room - Twin spot
2.3.1 Table, Plant Room - 15 lux (E)
[m] 16
26.7 46.7
46.6
41.1
14
60.9
63.4
49.2
60.7
57.4
48.3
12
66.1 [71.1]
57
68.3
54.2
58.4
40
39.1
55
64.4
51
64.1
42.6
50.4
39.7
44
47.8
45
61
69.6
57.2
69.4
55.6
66
58.5
59.9
60
57.8
47.4
59.3
68.6
51.5
68.3
52.2
64.6
56.8
54.5
49.6
49.1
65.4
62.5
70.9
54.2
70
53.3
66.3
57.4
58.3
61.2
56.1
63.8
4
52.6
61.2
51.5
63.2
48
62.1
49.8
57.4
54.2
48
2
26.4
30.6
27.6
32
24.5
30.8
25.7
29.1
26
(23.8)
28.4
30.9
29.1
33.1
25.3
31.7
26.5
30.4
27.1
10
34.5
8 6
0
0
2
4
6
8
10
12
14
16
18
[m]
Illuminance [lx]
Required minimum illuminance Minimum illuminance Maximum illuminance Uniformity Height Calculation algorithm used Maintenance factor
: 15 lx Emin Emax Emin/Emax
: 24 lx (* 14 lx) : 71 lx (* 75 lx) : 1 : 2.99 (0.33) (Threshold value 1:40) (* 1:3.00) :0m : Direct component : 0.8
*: Values on fine measuring grid (0.1m - 0.5m)!
produced by Ansell Lighting Design Department 29873 Moxy Stratford Plant Room Only Lighting Design 170802
Page 9/11
Object Installation Project number Date
2.3
: : : :
Moxy Stratford Plant Room Proposed Lighting Layout 99-29873-MG 02.08.2017
Calculation results, Plant Room - Twin spot
2.3.2 Boundary line, Plant Room - 15 lux (E)
[m] 18 16 14 12 10 8 6 4 2 0 0
Illuminance [lx]
15
2
4
6
150
8
10
300
Required minimum illuminance Minimum illuminance Maximum illuminance Uniformity Height Calculation algorithm used Maintenance factor
12
14
16
18
450
20
[m] 1 : 250 600
: 15 lx Emin Emax Emin/Emax
: 14 lx : 75 lx : 1 : 5.22 (0.19) (Threshold value 1:40) :0m : Direct component : 0.8
produced by Ansell Lighting Design Department 29873 Moxy Stratford Plant Room Only Lighting Design 170802
Page 10/11
Object Installation Project number Date
2.3
: : : :
Moxy Stratford Plant Room Proposed Lighting Layout 99-29873-MG 02.08.2017
Summary, Plant Room - Twin spot
2.3.3 Result overview (emergency lighting) Type No.\Make
2
24
ANSELL Order No. Luminaire name with Equipment with Equipment
: ATSLED/3NM/IP65/ST : Emergency - IP65 Owl LED Twin Spot : 1 x ATSLED/3NM/IP65/ST_H : 1 x / 442 lm (100.0 %) : 1 x ATSLED/3NM/IP65/ST_H : 1 x / 442 lm (100.0 %)
Result evaluation area Calculation algorithm used: Direct component Maintenance factor: 0.8 Reference planes for emergency lighting: Surface No. Default[lx] Emin[lx] Emax[lx] Plant Room - 15 lux 2 15.0 14.3 74.5
Uniformity Height 1: 5.22
0.00
produced by Ansell Lighting Design Department 29873 Moxy Stratford Plant Room Only Lighting Design 170802
Page 11/11